Calibration
Termatrac Calibration
All Termatrac devices require annual calibration to ensure consistent accuracy and to verify that all electronic components are functioning in line with test and measurement standards.Calibrating test and measurement equipment is essential for maintaining reliability and performance.Termatrac devices are vital tools for detecting movement, moisture, and temperature variations, supporting Pest Control Operators (PCOs) and Building Inspectors with accurate digital graphs and data presented in percentiles. However, without regular calibration, the accuracy and reliability of the measurements cannot be guaranteed. Environmental factors such as humidity and temperature fluctuations can impact results over time, while frequent use can lead to wear and tear on external components, further affecting data integrity.To maintain optimal performance and accuracy, Termatrac recommends that devices are calibrated annually. Termatrac Calibration Centres carry out comprehensive inspections, recalibration, and any necessary repairs to uphold factory standards and keep your device performing at its best.
Termatrac Calibration Process
The calibration of each Termatrac device is tailored to its specific condition. Typically, this process involves replacing any worn or damaged internal and external components that impact functionality, along with the firmware and hardware updates are also applied to ensure all mechanical parts meet specifications. Additionally, Termatrac offers a 12 month warranty upon calibration to uphold our commitment to maintaining measurement accuracy standards.
T3i Calibration Process: Price AUD385.00
(Does not include freight)
The calibration of each Termatrac device is tailored to its specific condition. Typically, this process involves replacing any worn or damaged internal and external components that impact functionality, along with the firmware and hardware updates are also applied to ensure all mechanical parts meet specifications. Additionally, Termatrac offers a 12 month warranty upon calibration to uphold our commitment to maintaining measurement accuracy standards.
1. Perform a complete initial functional check.
2. Inspect battery compartment, connections, and external hardware for damage; replace as
required.
3. Verify all internal and external connectors are checked.
4. Upgrade firmware to the latest version.
5. Radar- inspect and calibrate power output and sensitivity. Replace components which are
faulty and do not meet specification.
6. Moisture- Inspect and calibrate. Replace components which are faulty and do not meet
specification.
7. Temperature- inspect and calibrate accuracy and sensitivity. Replace components which are
faulty and do not meet specification.
8. Laser Pointer- inspect and replace components which are faulty and do not meet
specification.
9. Perform final Quality and Assurance check.
10. Provide Pass Calibration Certificate, QA label and apply next due date.
11. Update T3i with record of 12 month extended warranty from calibrated date.
12. Calibration Certificate provided.
Please Note: The T3i technology has become outdated, and sourcing electronic parts for the device has become significantly challenging. Consequently, we’ve introduced a new device to replace the T3i. Termatrac is committed to staying abreast of advancing technology.
iTraker Calibration Process: Price AUD275.00
(Does not include freight)
The iTraker calibration process is a comprehensive procedure designed to ensure each device operates to the highest standard of accuracy and reliability. All work is conducted in accordance with Termatrac’s factory specifications and quality assurance protocols.
Calibration Process Includes:
Conduct a full functional check of the device.
Inspect the enclosure and all external components for damage or wear; replace as necessary.
Inspect all internal connections and electronic components; repair or replace as required.
Inspect and test the battery to ensure proper performance.
Upgrade the firmware to the latest version available.
Radar Motion Sensor: Inspect and calibrate power output and sensitivity; replace any components that are faulty or outside of specification.
Moisture Sensor: Inspect and calibrate for accuracy and sensitivity; replace components as required.
Temperature Sensor: Inspect and calibrate for both accuracy and sensitivity; replace if necessary.
Laser Pointer: Test functionality and replace any faulty parts.
Thermal Imaging Camera – Conduct functionality testing and make calibration adjustments where required.
Replace the scuff pads to maintain device stability during use.
Perform a final quality assurance inspection to confirm all functions meet factory standards.
Upon successful calibration, the device will be issued with:
A Pass Calibration Certificate
A Quality Assurance (QA) label
A clearly marked Next Calibration Due Date
This process ensures your iTraker continues to deliver reliable, accurate results in the field.
For information about calibration please contact our Support Team.
Email: support@termatrac.com
Phone: +61 7 3386 3300
Or visit our website for our Distributors/Agents lists who can also assist you with online reporting within
your region.